HT9800-K2
Introduction
Weighing display controller (aluminum alloy shell)
Application
can be used for packing scales, proportion scales, screening scales, stabilization control devices for upper and lower limits control etc
Main Technical Index
Range of input signal: -10~+ 35mV
A/D conversion: 24-bit sigma-delta A/D conversion
A/D sampling frequency: 38.400 kHz
Nonlinearity:≤0.0015% F.S.
Gain error drift: 0.5ppm/℃
Minimum resolution: 0.1uV/d
Supply voltage: 5V/200mA (can connect 16 sensors)
Operating temperature: -10~+50℃
Storage temperature: -40~+85℃
Relative humidity:≤90% R.H
Power supply: AC187~242V, 49~51Hz
Hole dimension: 152 × 76mm
External dimension:162×86 × 145mm
Main Performance
Filtering progression adjustment (Grade 1-4)
No re-scaling is needed during instrument changing
16-channel on-off input/output
Automatic free fall compensation
4~20mA analog output
RS232C and RS-485 (optional) serial communication interface
Baud rate 1200/2400/4800/9600 (optional)
Anti-static electricity design was adopted for all interfaces to avoid damage